Stock code

300693

Battery module testing equipment series

Module power battery testing equipment has high energy density, wide output voltage range, the lowest discharge voltage can reach 5V, compatible with a variety of models of module battery test response speed, efficient energy feedback and other excellent performance, can be compatible with a variety of voltage and current levels of battery module for electrical performance test.

The product application

  • Battery cell production
  • Research on the test
  • Quality inspection
  • Step recovery, etc.
  • Minor changes between millimeters can also be easily explored.

    Accuracy of voltage and current is better than 0.05%F.S., automatic selection of current gear. According to the output range of different equipment models, it can be equipped with multi-current gear selection, and automatically select the most suitable current gear according to published parameters. Maximize the accuracy of test data to provide an accurate data basis for battery analysis.

    Condition simulation function

    The device simulates any current/power waveform of the battery during the actual driving process such as starting, climbing and braking, providing reliable and comprehensive data to help customers shorten the battery development/validation cycle.
  • 20ms

    Minimum time interval
  • excel

    Support EXCEL import of current/power conditions
  • 3 millions

    Working condition of article number
  • Fast current response, airtight

    Output current quickly reach the set value, support a variety of high-speed dynamic waveform and working condition simulation test.
  • ≤5ms

    Current response time
  • ≤10ms

    Current conversion time
  • Support a variety of fast dynamic waveform simulation test
  • Equipment linkage, a variety of environments catch up

    The equipment can be linked with BMS, water cooler, environment box, temperature, pressure and other sensors to form a high-performance detection system; The unified control of BTS software accurately evaluates the electrical performance of battery packs in various extreme environments, and uniformly controls and controls test equipment, making it convenient and simple to operate.

    High feedback efficiency facilitates green production

    The energy is transferred to the charging cell for direct utilization and feedback to the power grid. It has no pollution to the power grid, and can effectively reduce the power consumption of the power grid, save power, and greatly reduce the production cost.
  • >0.99

    The power factor
  • 90%

    Feedback
  • ≤3%

    Harmonic content
  • DCIR test

    The device provides a test method for battery DC internal resistance. It supports setting a value point and automatically obtains the required test result without manual calculation.

    BTS software, human-computer interaction one step ahead

    Battery detection and formation software is the background control system of battery production and testing system, mainly responsible for process step editing, test control, real-time data display, test process data recording and data analysis.
  • Centralized monitoring of multiple channels on different devices.
  • A variety of complex work step editing, multiple work step conditions combination judgment.
  • Generate data reports based on custom templates.
  • Data recording time:10ms
  • Safer test

  • Test safety

    Comprehensive software and hardware protection measures to prevent misoperation and abnormal conditions, to ensure the safety of testing backconnection protection, wire protection, work step self-inspection, trend protection, etc.
  • Data security

    When the ac power supply is interrupted, the device automatically records the power supply. After the power supply is restored, the device can resume the test and data is not interrupted. The dual-data technology prevents the loss of test data caused by manual or accidental operations.
  • Battery module testing equipment series
  • Charging voltage
    0V~60V
  • Discharge voltage
    5V~60V
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~100A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    85%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • Charging voltage
    0V~60V
  • Discharge voltage
    5V~60V
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~300A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    85%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • Charging voltage
    0V~60V
  • Discharge voltage
    5V~60V
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~600A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    85%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • Charging voltage
    0V~120V
  • Discharge voltage
    5V~120V(Discharge voltage 0V can be customized)
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~100A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    90%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • Charging voltage
    0V~120V
  • Discharge voltage
    5V~120V(Discharge voltage 0V can be customized)
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~300A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    90%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • Charging voltage
    0V~120V
  • Discharge voltage
    5V~120V(Discharge voltage 0V can be customized)
  • Voltage accuracy
    ±0.05%F.S.
  • Output current range
    0.1A~600A
  • Accuracy of current
    ± 0.05%F.S.
  • Charge and discharge efficiency
    90%
  • Response time of charge and discharge current
    ≤5ms
  • Charge and discharge current conversion time
    ≤10ms
  • CONTACTEZ-NOUS MAINTENANT

    Vous souhaitez obtenir des informations sur Sinexcel? Nous apprécions votre intérêt et serions heureux de vous conseiller.
    Donnez-nous simplement quelques informations afin que nous puissions vous contacter
  • Address
    1002 Songbai Rd,Nanshan Shenzhen China 518000
  • Hotline
    18727998133

  • E-mail
    mengxian_zeng@sinexcel.cn
    • Charges vary depending on service provider and country/region
    • Free of charge from German landlines and mobile networks; callers from abroad,
      please use the international number
  • * Sinexcel responsable de vos données personnelles. notre avis de confidentialité décrit les différents droits de protection des données dont vous disposez et la... Sinexcel responsable de vos données personnelles. notre avis de confidentialité décrit les différents droits de protection des données dont vous disposez et la manière dont vous pouvez exercer ces droits en ce qui concerne toute information que nous traitons de votre part, comme le droit d'accéder ou de recevoir une copie de vos informations ou de demander la suppression ou la correction de votre informations. Dans certains cas, vous pouvez vous opposer au traitement ultérieur de vos informations et, lorsque Sinexcel a demandé votre consentement pour traiter les informations, vous pouvez retirer ce consentement à tout moment.

    Pour plus de détails sur la façon dont nous utilisons les données personnelles et sur les droits de confidentialité des données, veuillez consulter notre avis de confidentialité complet.
    See more
  • Submitted successfully

    Details will be sent to your email later
    Close
    Details will be sent to your email later
    Close
    0755-8651-1588 sales@sinexcel.com